Meade LX200R Manuál s instrukcemi Strana 1

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Dalekohledy Meade LX200R. Meade LX200R Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 60
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Meade Instruments Corporation
Instruction Manual
16” LX200 Schmidt-Cassegrain Telescope
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - Instruction Manual

Meade Instruments CorporationInstruction Manual16” LX200 Schmidt-Cassegrain Telescope

Strany 2

- 10 -You can see CNTR (center) and GUIDE motions only whilelooking through the telescope. The red LED light next to theappropriate key (3, Fig. 6) li

Strany 3 - WARNING!

- 11 -g . Use the number keys to enter your longitude as above. Whencomplete, the display will look like Display 7.Display 7h. Press ENTER to complete

Strany 4 - Contents

- 12 -c. Loosen the R.A. lock-knob (2, Fig. 5) and rotate thetelescope so that the R.A. Vernier pointer (4, Fig. 5) andthe Hour Angle (H.A.) pointer (

Strany 5 - Smart Drive

- 13 -The telescope will automatically begin to track objects. Fromthis point, move the telescope only through the hand controller.Manual movements by

Strany 6 - Inspecting the Optics

4. Which Alignment Method to UseEach of the three methods described above has advantagesand disadvantages. The following table summarizes thesepropert

Strany 7 - The 16” Field Tripod

- 15 -Speed Keys (SLEW, FIND, CENTER, and GUIDE)The SLEW, FIND, CENTER, and GUIDE keys (6, Fig. 7) let youset the rate of movement (slew) speed in the

Strany 8 - 3. Collimating the Viewfinder

A connector for RS-232 communication even lets you performevery function of the keypad from your personal computer.ON/OFF SwitchWhen you move the ON/O

Strany 9 - Using the LX200 In LAND Mode

MODE FUNCTIONSTo view the separate modes within the LX200 system, pressthe MODE key ( it is located between the ENTER and GO TOkeys at the top of the

Strany 10 - 1. Entering Basic Information

- 18 -This shows the alignment error that may have been madeduring your initial setup. Re-center the Pole Star duringeach interval using the pier

Strany 11 - 4. Setting Up the Telescope

2. Using the HOME Alignment Routine: Using the HOMEalignment routine requires only two steps (assuming theSEThas been performed). First, before turnin

Strany 12 - 200 can yield ambiguous data

NOTE: Instructions for the use of optional accessoriesare not included in this manual. For details see theMeade General Catalog.The Meade Schmidt-Cass

Strany 13 - Star Alignment

- 20 -j. SLEW RATE: Option #10 in the TELESCOPE menu is forchanging the slew rate of the telescope. Slowing down theslew rate results in less noise wh

Strany 14

You can use the object library in the following ways:Directly access the library by using the M, STAR, or CNGCkeys (see THE LX200 KEYPAD HANDCONTROLLE

Strany 15

d. PARAMETERS: Press ENTER at the PARAMETERS menuto find options that let you set such parameter limitations onthe objects that you wish to locate as

Strany 16

- 23 -magnitude.8. FA I N T E R : You may also adjust the upper level ofbrightness with the FAINTER menu file option, (you mayfind few applicat

Strany 17 - MODE FUNCTIONS

- 24 -battery-replacement information). Mode Four:TIMER/FREQ1. The TIMER OptionThe TIMER menu option is for accurately timing differentobserving or im

Strany 18 - 200 in an observatory or

- 25 -the image starts to become fuzzy as you work into highermagnifications, then back down to a lower power (as whenthe optometrist asks, “Is this l

Strany 19 - Center STAR XXX

- 26 -APPENDIX A: EQUATORIAL USECelestial CoordinatesCelestial objects are mapped according to a coordinate systemon the Celestial Sphere. This is the

Strany 20 - 2. OBJECT LIBRARY Menu File

- 27 -d. The telescope slews to Polaris’ position. Using the azimuthand latitude controls on the permanent pier, center Polarisin the field of view. D

Strany 21

- 28 -APPENDIX B:LX200 ALIGNMENT STAR LIBRARYAND STAR CHARTS:Alignment StarsThe LX200 utilizes the following 33 bright, well known stars tocalibrate t

Strany 22

- 29 -Star Charts(for Northern Hemisphere Observers)NORTHMay 7:00 to 9:00NORTHJune 7:00 to 9:00SOUTHWESTMarch 7:00 to 9:00NORTHApril 7:00 to 9:00SOUT

Strany 23 - AZ = 158'10

WARNING!Never use the LX200 telescope to look at the Sun! Looking at or near the Sun will cause instantand irreversible damage to your eye. Eye damage

Strany 24 - FREQ = 60.1M ◊

- 30 -NORTHJuly 7:00 to 9:00NORTHSeptember 7:00 to 9:00NORTHWESTNovember 7:00 to 9:00SOUTHEASTDecember 7:00 to 9:00NORTHOctober 7:00 to 9:00NORTHAugu

Strany 25

APPENDIX C:LX200 64,359-OBJECT LIBRARYThe LX200 64,359-object library is a collection of the moststudied and wonderful objects in the sky. The library

Strany 26 - Using the LX200 in POLAR Mode

The CNGC distinguishes the following object types.About the Index Catalog (IC)The IC reproduces the complete Index Catalog of a variety ofobjects that

Strany 27 - Precise Polar Alignment

The CNGC CatalogCNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS0045 00 14.0 -23 10 486 10.4 GALAXY S- IV-V UGC A4

Strany 28 - LX200 ALIGNMENT STAR LIBRARY

CNGC Catalog (continued)CNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTS1746 05 03.6 +23 49 2520 6.1p OPEN CLUS c 1 S

Strany 29

CNGC Catalog (continued)CNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS2437 07 41.9 -14 49 1620 6.1v OPEN CLUS sp=

Strany 30

CNGC Catalog (continued)CNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS4349 12 24.2 -61 54 960 7.4v OPEN CLUS c 1 S

Strany 31 - * * object is not in the RNGC

CNGC Catalog (continued)CNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTS5927 15 28.0 -50 40 720 8.3v GLOB CLUS b 2 ST

Strany 32 - The Planet Catalog

CNGC Catalog (continued)CNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTS6523 18 03.2 -24 23 5400 5.2 OPEN CLUS + ENE

Strany 33 - The CNGC Catalog

- 39 -CNGC Catalog (continued)CNGC# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTS6981 20 53.5 -12 33 354 9.4v GLOB CLUS

Strany 34 - CNGC Catalog (continued)

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5What is the LX200? An Overview. . . . . . . . . . . . . . . 5 . . . 1. Hea

Strany 35

The Star Catalog STAR# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS* 1 00 08.3 +29 06 2.1v STAR B8.5p IV:(Hg+Mn) Alp

Strany 36

The Star Catalog (continued)STAR# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS* 61 06 22.9 +22 31 2.8v STAR M3 IIIab

Strany 37

The Star Catalog (continued)STAR# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTS*121 12 26.6 -63 06 50 1.3v STAR B0.5 IV

Strany 38

The Star Catalog (continued)STAR# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTS*181 16 41.3 +31 36 11 2.8v STAR G1 IV +

Strany 39

The Star Catalog (continued)STAR# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS*241 22 05.8 -00 19 3.0v STAR G2 Ib Alp

Strany 40 - The Star Catalog

The Star Catalog (continued)STAR# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTS*301 12 26.6 -63 06 47 1.6 STAR 1.6:2.

Strany 41 - The Star Catalog (continued)

The M (Messier) CatalogM# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME Q TAGS COMMON NAME/COMMENTSM 1 05 34.5 +22 01 360 8.4 PLAN NEB EMIS SN

Strany 42

The M (Messier) Catalog (continued)M# RA DEC SIZE MAG TYPE & DESCRIPTION ALT NAME QTAGS COMMON NAME/COMMENTSM 61 12 22.0 +04 28 360 9.7 GALAXY S

Strany 43

APPENDIX D:MAINTAINING YOUR LX200Keeping Your Telescope Clean and DryPreventive maintenance is the best course for keepingastronomical equipmen

Strany 44

You can clean the interior of the optical system yourself or haveit done professionally. If you do it yourself, handle the opticsvery carefully. Any i

Strany 45

- 5 -INTRODUCTIONAs a new LX200 owner, you are preparing for a journey into theuniverse with the most advanced amateur telescope everproduced. This in

Strany 46 - The M (Messier) Catalog

5. If, while turning, you feel the screw get very loose, tighten theother two screws by equal amounts. If while turning, the set-screw gets too tight,

Strany 47

APPENDIX E:LX200 PERSONAL COMPUTER CONTROLRemote operation of a computerized telescope has been only adream for most amateur astronomers. The realizat

Strany 48 - MAINTAINING YOUR LX200

To enter the test program, first load BASIC or GWBASIC(whichever your computer system uses), then type in the LX200T E S T program. When complete,

Strany 49

Command :Gt#Returns sDD*MM#Gets the latitude of the currently selected site.Command :St sDD*MM#Returns OkSets the latitude of th

Strany 50 - (1) (2) (3)

Command :Sh DD#Returns OkSets the current “higher” limit.Command :Go#Returns DD*#Gets the current “lower” limit.Command :S

Strany 51 - 200 PERSONAL COMPUTER CONTROL

- 55 -LX200 Demo ProgramThe RS-232 interface communicates with your computer at9600 baud rate, parity = None, 8 data bits, 1 stop bit. Forthose who

Strany 52 - LX200 Command Set

- 56 -telpos:LOCATE 6, 7: PRINT "TELESCOPE POSITION";c$ = "#:GR#": PRINT #1, c$; : d$ = INPUT$(8, 1): RAL$ = LEFT$(d$, 3):RAM$ = M

Strany 53 - 5. Library/Objects

- 57 -status:LOCATE 1, 7: PRINT "SITE"c$ = "#:Gt#": PRINT#1, c$; : d$ = INPUT$(7, 1): RAL$ = LEFT$(d$, 3):RAM$ = MID$(d$, 5, 2): L

Strany 54 - 6. Miscellaneous

- 58 -drawbox:REM LOCATE BOXSTX, BOXSTY:REM BOX$ = CHR$(201)REM FOR I = 1 TO BOXWIDE: BOX$ = BOX$ + CHR$(205): NEXTREM PRINT BOX$;RETURNhelp:LOCATE 14

Strany 55 - LX200 Demo Program

- 59 -APPENDIX F:LX200 SPECIFICATIONSTelescope 16”LX200 f/10Optical Design Schmidt-CassegrainCatadioptricClear Aperture 406mm (16")Primary Mirror

Strany 56

- 6 -16” LX200 uses only one motor to track, and in this caseSmart Drive corrects for periodic error in one axis only.Smart Drive uses a model of the

Strany 57

Ver 01099 Part no. 14-108MEADE LIMITED WARRANTYEvery Meade telescope, spotting scope, and telescope accessory is warranted by Meade Instrume

Strany 58

Commercial shipment of the 16" LX200 Telescope without thesafety bolt in place and packed in the original factory suppliedshipping containers as

Strany 59 - Telescope 16”LX200 f/10

Attaching the 16” Drive Basea. Rotate the field tripod so that one leg is pointingapproximately South (it need not point exactly South).b. Po

Strany 60

Southern Hemisphere OperationThe 16” LX200 is shipped with the North/South jumper set forNorth (i.e., with the jumper on one pin only). This jumper is